Specifications:
DESCRIPTION AND APPLICATION
- ZIKA 316L is designed for 100% CO2 gas shielding and all-position welding.
- It exhibits excellent slag release and almost spatter-free operating features.
- It can be used for joining types of 316,316L, CF-8M, and CF-3M stainless steels.
- It provides high inter-granular corrosion resistance to pressure vessel application due to the low carbon content.
- Before welding, the base metal should be cleaned from oil, rusty, moisture and the welding place should have the proper protection from the wind.
- Use 99.8% or higher purity CO2 as shielding gas.
- Maintain the flow rate no under than 20L/min when wire diameter is 1.2mm.
- Trailer Shield is required to ensure the weld pool completely shielded until solidification is complete and no porosity problem.
- Keep dry while in storage and delivery.

TYPICAL ALL WELD METAL COMPOSITION [WT%]
C |
Mn |
Si |
P |
S |
Ni |
Cr |
Mo |
0.027 |
0.69 |
0.025 |
0.010 |
0.011 |
12.63 |
18.8 |
2.68 |
TYPICAL ALL WELD METAL MECHANICAL PROPERTIES
Yield Sress [MPa] |
Tensile Stress [MPa] |
A5 [%] |
Impact [ISO-V] |
– |
560 |
42 |
– |
Use 99.8% or higher purity of CO2 gas
Parameter |
Diameter |
1.2 mm |
F |
130A~220A / 24V~33V |
HF |
130A~220A / 24V~33V |
H |
140A~180A / 25V~29V |
VU |
130A~160A / 24V~28V |
OH |
150A~180A / 25V~29V |
DC(+) polarity